how to choose steam boiler for sugar factory coal
Narrative Gas Gas stove three steam transformation of energy-saving methods in recent years, with the continuous development of the boiler industry, a variety of devices including gas, including gas-steam oven has been further developed and applied. We know that each device can produce a wide range of applications, and can be explained. With their own advantages, the main advantage of what we are talking about today is a gas oil furnace? According to reports, it can be learned, gas furnace gas and steam coal ash accumulation is not required, thus eliminating area. When the gas for a fuel delivery gas steam oven, other auxiliary machines less, low-power, continuous operation time is short, and therefore at a high level, saving electricity. Production of heat transfer oil boiler. Others because the gas will now be run out of gas and steam road dust and pollution, natural gas is used as a clean energy source. In the Gas Gas steam oven operation, no pollution, and it is easy to achieve. Nightly environmental needs. Steam Gas Gas stove three energy-saving methods: a: heat pipe heat recovery boiler technology tube warm end of the heat recovery boiler installed in the mouth, high temperature flue gas generated during operation of the boiler can be recycled, cleaning, recycling heat boiler thermal efficiency can be improved. Reduce fuel consumption, save energy. And in the process, it can reduce exhaust emissions, reducing environmental pollution, to achieve environmental protection. II: Use scaling, cleaning technology uses boiler detergents, electronic antifouling agent, softened water treatment apparatus, optimize the steam cycle system, removal of calcium and magnesium ions, demineralized water, to reduce scale formation, to control the discharge of sewage. boiler. rate. 3: Use fuel additive which is added some additives in the fuel, gas and steam gas furnace design is to optimize the fuel, thereby reducing the size of the boiler, improving the thermal efficiency.
After the gas hot water boiler hot water boiler vaporization emergency 1. Vaporization handler circulating pump stops abnormally pump failure caused by: ① blower stops running immediately. ② immediately open the door, take measures to pressure the fire, lift the chute gate, cutting off the supply of coal grate. ③ In the case of boiler pressure not greater than 0.6MPa (600KPa), the exhaust valve to follow, only a sharp rise in pressure in the boiler deflated, used only relief exceeds 0.9MPa, and the exhaust process to be carried out slowly, prevention boiler due to loss of pressure and more violently again vaporized. ④ close the boiler water, water main gas valve. ⑤ open stop valve recirculation line, to ensure that the water supply pipe velocity convection heating surface (economizer) to prevent re-vaporization of the economizer. ⑥ The operation of the above operation, at the same time to pay the boiler to reduce the boiler water temperature and the furnace pressure. ⑦ After the boiler pressure is normal, i.e., opening the standby circulating pump, into the normal combustion. 2. Treatment failure or sudden loss of power boiler vaporization of power: ① immediately open the door, lift the coal chute slide gate to take pressure fire measures to reduce the oven temperature. ② Grate with the fastest speed in order in the shortest time to fire onto the slag tap. ③ the degree of treatment in the first case. Once a short time can not supply heating network system, antifreeze should take emergency measures. 3. Due to excessive heat boiler boiler vaporization process: ① the immediate closure of the drum, induced draft fan. ② immediately open the door, take measures to pressure the fire, lift the supply of coal chute slide gate, off of coal, while the grate into fast gear. ③ In the case confirmed the presence of water, the boiler can supply water to the boiler body, boiler out of the water while closing the main valve. ④ Open line stop valve recirculation pump to ensure water velocity convection heating surface of the pipe, to prevent the economizer again vaporized. ⑤ Open circulating pump with jog mode, jog each time less than 30 seconds, again less than one minute jog interval. Jog purpose is to reduce the boiler water temperature, while preventing a large amount of steam into the pipeline system. ⑥ back into place after the safety valve, circulating pump running, and then the normal burning stove. 4. Water boiler system run vaporization process due to water loss, loss of pressure caused by: ① immediately closed drum, induced draft fan. ② out of the water while closing the main valve and the boiler circulating pump. ③ take the same measures to cool the furnace tube described above. ④ Open stop valve recirculation line. ⑤ rely exhaust valve until the safety valve back into place. ⑥ until the boiler water temperature drops below 50 ℃, when the temperature of the furnace temperature less number 200 ℃, again within the boiler feed water, water course to be carried out slowly, to prevent harm to the boiler when the temperature is too large. ⑦ After processing leakage fault, the system time to the replenishment, and out of the water boiler always open the valve, and the circulating pump, and then normal combustion.
Fast boiler is a very trustworthy business, whether it is the beginning of cooperation or boiler put into operation, such as a party soon have maintained cooperative attitude, patience, careful. To ensure long-term stability of the latter part of the boiler operation, fast boiler technician fireman's gave us a free people to do the training, precautions and reduce the accident rate method full guidance boiler operation. --customer feedback
Distinction gas how to choose steam boiler for sugar factory coal and a conventional coal-fired boilers and gas steam boiler (1) in a conventional coal fired boiler should be prechamber through grinding equipment, coal should be produced for combustion injected into the furnace, the entire combustion process in furnace and in the form of a suspension. (2) as long as the gas steam boiler biomass fuels open, dried and crushed, the helical feeder to the air before it is blown into the top of the combustion grate vibration. After burning the soot removed from the baghouse gas steam boiler. 2, different air supply preheating. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing user fees (1) coal-fired boiler air preheater flue at the bottom, below the economizer; using flue (2) temperature of the air supply end of the cigarette is heated, different from a conventional boiler, the feed gas steam boiler air preheated by the air preheater flue gas cooler and the two parts to feed water as a medium to absorb heat of the flue gas, conveying air into the furnace. Warm air supply system for a gas steam boiler is controlled by adjusting the supply air temperature of the heating water flow can be provided by adjusting the electric charge of the bypass track circulation water through the valve and the air preheater flue gas cooler bypass control. Water heat exchange section, cooling water heated through the air preheater and the cold air delivery fan; then, this part of the water continues to flue gas cooler, flue gas by exchanging heat with water in the flue gas cooler, water heating, cooling the flue gas. In the bypass, a bypass flue gas cooler and another bypass air preheater, both have their own electrical control bypass and isolation valves. When the flue gas cooler exit gas temperature is too low, the bypass isolation valve is opened, water does not pass through the flue gas cooler, flue gas heat exchanger is not performed to ensure the flue gas cooler outlet gas temperature is not too low smoke corrode gas cooler. In order to enter the flue gas cooler feedwater temperature is not too low, when the air preheater outlet water temperature is below a certain temperature, it opens the bypass, supply cool air can not be heated, the water temperature is too low to prevent the influence of the flue gas cooler work . But also to ensure the temperature of the flue gas through a gas steam boiler precipitator. 3. The coal-fired boiler flue gas fired boiler bag filter should be used for desulfurization libraries to ensure the emission of pollutants lower than the standard. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. Gas hot water boiler with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. However, biomass combustion flue gas are different. Biomass fuel of low sulfur and nitrogen content, only through the biomass filter before discharge into the atmosphere. However, the carbon content of fly ash produced by the combustion of biomass, coal-fired boiler boiler efficiency is better, but the carbon dioxide content in the greenhouse can be reduced. Under the same nitrogen content of the fuel, the nitrogen oxides emission concentration of boiler far below the emission standards for coal-fired boilers. The problem should be noted that operation of the gas boiler. From the operational perspective view of the gas boiler, the operation of the gas boiler should note the following: The actual fuel consumption of the boiler operation, the amount of oil to the adjustment screw feeder. Unburnt fuel in the furnace, induced draft fan and the blower can not be stopped. Sudden power outage in operation, must be promptly removed fuel furnace. Not add biomass fuel before the shutdown. When the furnace stopped, there is no need of the bank up a fire. When the fuel on the grate exhausted, drum induced draft fan may stop running. If you want to know more about boiler, gas steam boiler, you can log on to our website, we look forward to your call!