WNS series industrial gas fired steam boiler
In response to the state-assigned air quality improvement objectives and environmental supervision central feedback coal-fired boilers environmental pollution rectification program, Kang County, Gansu Province based on "government-led, relying on real responsibility, Take Measures to proceed with" principle, accelerate the burning of remediation work out of the coal boiler, and to develop the following measures, at present, reconstruction activities are being actively promoted.
A: a comprehensive investigation, the establishment of accounting. For urban areas, towns, Kudo industrial parks all coal-fired boilers to conduct a comprehensive diagnostic investigation, a total of investigation and the use of the boiler 31 enterprises, a total of 38 boilers, electric boilers and removal of fuel two boilers, coal-fired boilers county a total of 36, including two sets of 20 tons of steam boilers, coal-fired boiler pressure 4. In the diagnostic process, the situation boiler location, type, number of units, the tonnage, use, carefully verify the age and so on, and sort out the summary, so that a boiler does not leak, the device information is not a shortage.
Two: to strengthen publicity, and create atmosphere. Through new media, focus on advocacy, government circulars issued, will be held to promote the government leaders in charge of on-site investigation led mobilization and other forms of media offensive formation, multi-level multi-angle carry out various forms of publicity and education remediation phase out coal-fired boilers, each guide society personnel support and participate actively promote the use of coal-fired boiler units understand the situation, to speed up the phase-out of coal-fired boiler renovation.
Three: supervision of interviews, results-oriented. Person in charge of the county Bureau of Quality Supervision led, in-depth coal-fired boiler unit, for the slowness, lack of knowledge, waiting to see the business units and enlighten them with reason, and emotionally moving. With the responsible persons of the two job interviews lag to not be one of them out of the situation Reconstruction of boiler in accordance with national policy requirements, on-site recovery boiler registration certificate and ordered deadline to be removed or modified.
Kang mentioned standard by the transformation, step out, closed down closed down, to gas and electricity from coal to supervise a number of measures to actively promote the elimination of remediation coal-fired boilers. Currently the county out of 29 coal-fired boiler units, of which 15 units destructive demolition, stop burning close 12 stations, two mentioned standard transformation. The remaining seven out of focus on remediation plan included in this year, the county continues to promote this work, and to call on the unit enthusiastic, standards do not fall, the team leave, determined to complete the end of October this year, the county and below 10 tons of steam coal-fired boiler work all clear.
Gas-fired wns series industrial fired steam boiler safety valve from installation to use, it must remain vigilant safety valve is one of the most important components of the gas steam boilers, boiler probability of the risk occurring due to various incidents can effectively suppressed. This article focuses on the safety valve from installation to use several important considerations, we do not ignore the use of gas when it steam boiler. A Notes 1 safety valve, the safety valve should be mounted vertically in a high position in the pot business, set box. 2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly. 4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm. 5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of the passage should not step short tube to 1.25 times the area of all the exhaust valve. 6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. 7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve. 8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve. 9, separable economizer outlet, the steam superheater outlet valve must be installed.
The working principle of wns series industrial fired steam boiler steam boiler with boiling water almost equivalent to pot kettle, oven stove equivalent. Boilers and boiler furnaces is divided into two parts, the pot is filled with water to a metal container, partially combusted fuel furnace, the heat absorption of the water inside the pot furnace fuel combustion converted to steam. Popular terms, the steam boiler is to absorb combustion heat of the fuel into the water some parameters (such as pressure, temperature, etc.) of the steam device. For example, everyone knows to pulverized coal, for example. 1. The operation principle (an example in pulverized coal fired boilers) in heat pulverized coal combustion furnace, radiative heat transfer is first absorbed by the water wall, the Wall Boiling water, a large amount of steam into the drum for steam separator (DC furnace excluded), the separated saturated steam enters the superheater, and continues to absorb the furnace top horizontal flue by means of radiation, convection, heat of the flue gas flue of the tail, and the superheated steam to reach the required operating temperature. Power generation boilers are generally provided with a reheater, it is used to heat the steam through the high pressure cylinders acting reheater go out of the reheat steam, the low pressure cylinder to continue to generate power. 2. Pulverized work, the center position of the flame will impact the amount of evaporation, generally, the lower the evaporation flame kernel, the flame kernel high evaporation amount is small; also affects the position of the center of the flame superheated steam or reheat steam temperature, generally lower the center of the flame in particular superheated steam reheat steam temperature to be low, otherwise higher. 3. The arrangement of the burner, pulverized coal fired boiler on, the current embodiment there are opposed wall, more Tangentially combustion, combustion bis Tangentially the like, each have their own characteristics, can not be applied because the same furnace at the same time several above-mentioned arrangement, the steam still can not directly affect the conclusion.
Henan gas boiler tube leak detection device alarm Fault Henan furnace gas boiler tube leak detection device can be checked promptly internal gas boiler heating surface Henan leak case, can effectively protect other heating surface tube row, ensure the safe operation of the economic unit. 1. Symptom: (1) one side surface of the entire heating furnace tube leak detection alarm device. (2) concentration of several parts tube leak detection alarm device. 2. Analysis: (1) Henan compressed gas pipeline leak around the boiler emits different sounds. (2) sootblower valve lift Jam, steam leakage. (3) heating surface tube bank or weld leak squib. 3. Treatment: (1) contact electric inspection personnel. (2) no abnormal sound in Henan gas boiler furnace, whether near the flange of the compressed air line check alarm leak detection means has tube leaks and timely manner. (3) Check the tube near the sootblower alarm if a valve lift leakage detecting means there are leaks and timely manner. (4) such as opening hole to see the fire, obviously abnormal sound in the gas boiler furnace Henan, Henan description gas boiler tube leakage indeed, organizers prepare repair. 4. precautions: (1) strengthen inspection. (2) Electric regularly cleaned and checked Henan gas boiler tube leak detection means. (3) make Henan gas boiler tube leak repairs should be tight plan.