gas fired hot water industrial boiler
The following are the nine safety devices gas steam fired hot water industrial boiler. 1, water level monitoring: the original four water level is detected on the basis of a new fifth level detection, water level in cooperation with electronic detection devices, more comprehensive monitoring of boiler water level. 2, set the time: the user can set the starting time required to stop the boiler, free combination, convenient and flexible. 3, leakage protection: when the control system detects leakage electric heating elements, will automatically cut off power to prevent leakage fault occurs. 4, water protection: When the boiler water promptly cut off the gas burner control circuit to prevent the occurrence of dry damage the burner, while the controller sends water alarm indication. 5, power anomalies protection: Upon detection of a power failure, the boiler will stop running immediately. 6, the interlock overpressure protection: When the boiler pressure exceeds the user set value, the burner operation is prohibited and the alarm. 7, pressure controller, water level alarm, safety valve, low water level alarm and other multiple security. 8, a complete gas valve and protection system: providing a gas valve and accessories from whole filter, regulator and solenoid valve, ensuring safety gas. 9, real-time monitoring of flue gas: exhaust gas temperature of the boiler can be automatically monitored more easily grasp the combustion boiler.
At present several common fired hot water industrial boiler energy-saving technologies: usually for boiler manufacturers, it means that you are saving boiler to maximize the interests of customers, providing customers with unlimited fuel savings, the electricity consumption, water consumption and so on. But the wide range of energy-saving, does not refer to an aspect of optimization can save energy boilers, here's a look now common boiler energy-saving technologies: 1 furnace arch. Industrial boiler furnace arch is very important. Arch role is to cause the furnace hearth and the organization of the mixed gas and the radiation hot flue gas flow, ignition and combustion of the fuel in a timely manner. At present, the actual amount of industrial steam boiler with its rated load often do not match, the use of coal varies widely, but often with the design coal are quite different, so in actual use, often as necessary for the furnace arch modified to meet the needs of coals. Heteroaryl coal used by the inferior design coal, the boiler furnace exit gas temperature occurs is low (about 700 degrees), lower than 200 degrees design.
The development trend of environmentally friendly eco-friendly hot water fired hot water industrial boiler hot water boiler ushered in new opportunities. Late last year the State Council issued energy-saving environmental protection industry. Environmental protection boiler is also more and more attention in the boiler industry, in which major favorable policies, the mountain pot boiler seize the opportunity to develop environment-friendly hot water boiler, and its development trend did some summary for everyone to share now study and discussion, together with the conduct. The development trend of environmentally friendly hot water boiler specifically in the following areas: high-efficiency boilers; using simple auxiliary sets; simple structure; the whole intelligent automatic control and is equipped with multiple-level protection system. Environmentally friendly hot water boiler is on the whole have the following requirements: size and weight were reduced, which reduces the footprint of hot water boilers, boiler room would not need so much construction, weight reduction will saving materials, use of new materials to replace the old materials to improve the life of the hot water boiler, also during transport in many aspects, reduce unnecessary trouble. Improve boiler efficiency reduces fuel combustion, thus reducing the consumption of natural emissions of flue gas and water; and increase the degree of automation assembly, boiler maintenance so it will be more convenient, where you do not have the repairs carried out accessories and replacement is simple and convenient, automatic application of the procedures boiler with higher intelligence. Especially in recent years, the use of some new combustion technology and enhanced technology, the volume of oil and gas hot water boiler heat transfer is greatly reduced than before. Our industry has made great strides in development, people's general requirements of hot water boiler will be more stringent. This requirement is mainly to solve the contradiction between economic, security, usability. Mountains pot hot water boiler with a mature technical team, developed a hot water boiler in line with customer requirements for environmental protection, we have made many achievements in the hot water boiler market. Our mountain pot boiler satisfied with the existing results, as always, based on the market, focus on the future, to develop more high-quality environment-friendly hot water boiler, make a contribution to environmental protection. Gas boiler steam cleaning and maintenance measures combustion gas steam boiler is first opened the door, the rear housing panel removed, screwing the rear open boiler cleaning opening. Clean fuel gas piping with a wire brush. With a soft brush to clean the combustion chamber. Gas steam boiler to remove residue in the boiler, the cleaning opening is screwed on the screw, closing the burner door seal check is complete. If the boiler is installed in areas where temperatures below 0 ℃ must take the following precautions: If outside the boiler room, the room temperature drops below 15 ℃ or 18 ℃, the whole day operation of the boiler. If a long time no one in the room should be emptied of water in the boiler. You know cathodic protection of each member constituting the boiler (such as iron, copper, aluminum, etc.) of different materials. In order to prevent galvanic corrosion, cathodic protection measures must be taken. Sewage treatment boiler. The bottom of the gas-fired boiler flue gas emissions to prevent condensation. Since the flue gas is flue gas condensation (diesel or natural gas) and the flue gas temperature in the aqueous too low, water generated. A portion of the moisture is discharged from the chimney, the chimney wall is absorbed, the rest is deposited on the bottom of the chimney. Water produced by the following factors influence: flue gas temperature (efficiency 91%, the flue gas must be at a temperature of 170 ℃) where the total surface area heat chimney, chimney and chimney material. Maintenance of the burner. Gas boiler and burner maintenance, the best maintenance after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion burner door opened first time in memory, leaving the boiler is too long, remove the rear housing panel, tighten the screws to open the rear side of the boiler clean mouth. Clean fuel gas piping with a wire brush. With a soft brush to clean the combustion chamber. Gas steam boiler to remove residue in the boiler, the cleaning opening is screwed on the screw, closing the burner door seal check is complete. If the boiler is installed in areas where temperatures below 0 ℃ must take the following precautions: If outside the boiler room, the room temperature drops below 15 ℃ or 18 ℃, the whole day operation of the boiler. If a long time no one in the room should be emptied of water in the boiler. You know cathodic protection of each member constituting the boiler (such as iron, copper, aluminum, etc.) of different materials. In order to prevent galvanic corrosion, cathodic protection measures must be taken. Sewage treatment boiler. The bottom of the gas-fired boiler flue gas emissions to prevent condensation. Since the flue gas is flue gas condensation (diesel or natural gas) and the flue gas temperature in the aqueous too low, water generated. A portion of the moisture is discharged from the chimney, the chimney wall is absorbed, the rest is deposited on the bottom of the chimney. Water produced by the following factors influence: flue gas temperature (efficiency 91%, the flue gas must be at a temperature of 170 ℃) where the total surface area heat chimney, chimney and chimney material. Maintenance of the burner. Gas boiler and burner maintenance, the best maintenance after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion in the boiler stay too long memory
In this exhibition, we show the model, a video presentation that explains personnel foot work, a lot of foreign friends are also attracted to our show. Many domestic and foreign merchants, our products had a strong interest in, our staff have to ask for specific information material and consult the fired hot water industrial boiler. These are marks the company's importance for the market segments, and user demand for in-depth study. The future, the overall state of the market fast boiler will be in the "intensive" development path forward, provide good quality and good quality of boiler equipment more industry users.