Fire Tube Low Pressure Industrial 1 Ton Gas Steam Boiler
Our industry is a big country, provide power for industrial equipment giant multi-boiler. After investigation, the vast majority of our country's industrial boilers are in healthy condition, causing energy waste and pollution is very alarming. Moreover, the recent nationwide boiler accidents continue to occur, causing huge casualties and property losses, the adverse impact on society and the economy, how to effectively protect the safe operation of the boiler to be solved throughout the boiler industry event.
Steam and hot water boiler water level gauge fault safe hydraulic machine operating company of Henan fast boiler with small series to introduce a common fire tube low pressure industrial 1 ton steam boiler water gauge Problem safe operation of steam and hot water boiler water gauge failure of hydraulic machine, the causes and solutions approach a hot water boiler steam water gauge reason and common problems: 1, the water level is too low mounting table; 2, water table, even the water pipe is too small; table 3 have low level or a water level indicator, when active, only one only water table; 4, the ground water table, drain cocks no drainage; 5, a drum water level on the table is valid, another water table damage; 6, the tap water gauge screw fixed; 7, the tap water gauge leak, leaking; 8, the performance of the water table level false; 9, the drum water level in the water table irregularities two inconsistent; water gauge glass often broken; 11, water level gauge glass without guard; 12, water gauge low water level glass plate not shown in the red line instructions; 13, glass plate dirty water table, the water level observation is unclear. The main reason is because of 1-4 above design, installation or alteration of dislocation caused. When the steam boiler with a low water table position when the drum is only a case of the water table, water table because the internal balancer lowland leakage short-circuit (at that time can not be detected), resulting in the emergence of lowland water table high water level ( the so-called full of water), and the water table on the drum performance but low water level (or even probably not see the water level), then the fireman because they can not determine the true level of the boiler will go immediately and check the water level in the drum on the table, it will be very serious water shortage in container delays when the boiler accident occurred. Glass-sided water table in front of a glass sheet metal frame box lined with asbestos pad contact surface made of cardboard and then screw the cover frame and the cover pressure closely. Some even show the water level too low trust status of the water table, and take a little sewage, mistakenly steam boiler water when filled with water incident handling, accelerate the production of the accident, there is precedent for such incidents to be investigated. Then, the above-mentioned reasons hinder 5-9 problem occurs mainly boilers lasting not run when washed in water table, not routine maintenance, resulting in water gauge cocks rust, gas, water and even the block, or insufficient packing or aging deterioration. False water level phenomenon, in addition to gas, water or even the cock pipe is blocked, but also could be vapor, the water pipe connected to the water table caused by misalignment connection; steam, water tap handle installed the wrong position resulting cock closed, since there poor water quality, the boiler priming and thrown false water level. Water gauge glass is broken mainly steam, water faucet centerline not aligned, the presence of glass bending stress; long glass without expansion gap; water table is at the window glass is a cold draft, and the glass pipe quality was poor. Safe operation of hydraulic machine 1, hydraulic machine operator must be trained to master the equipment performance and operating techniques to work independently. 2, before the operation, you should clean up various debris on the mold, wipe any dirt hydraulic rod. 3, the mold must be installed hydraulic machine in case of power failure, and prohibit the collision start button, the lever foot on the footswitch. 4, installed on the upper and lower dies, the die gap adjust, unilateral allowed off-center, a good confirmation of the fixed mold pressure again. 5, before the hydraulic machine is first started working apparatus idling 5 minutes while checking whether enough oil tank, pump noise is normal, the hydraulic unit and pipes, fittings, if the piston leakage phenomenon.
Boiler multiple protection: (1) the integration of boiler water level to protect water level and boiler design, the appearance of more compact appearance, accurately show the actual water level in the boiler body function. Coupled with dual independent electronic water level control system to achieve ultra-low water level in the boiler, low water level automatic adjustment function, the normal water level, high water level, ensure that the boiler in a variety of unforeseen circumstances foolproof, secure home. (2) steam pressure protection ☆ pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switch, other control lines or automatic control chain protection. Common pressure controller and pressure gauge, vapor pressure overpressure alarm can cut off the burner limit is reached; the pressure controller may be single or double fire burning fire the actual operating pressure regulator. ☆ safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. (3) having a burner flame protection flame protection inlet means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged combustible residual gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. (4) self-locking power failure protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.
Gas-fired fire tube low pressure industrial 1 ton steam boiler is an advantage on the device using an environmentally friendly energy-saving: With the designers re-design of mechanical innovation, simple and easy to operate equipment, gas steam boiler is not only relatively simple, and better ensure the safe operation of ; saving advantages: high-temperature low-pressure gas steam boiler with a characteristic greatly reduces the stress levels of heating equipment, less direct advantage is the reduction in equipment investment. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. It was also said that the proportion of contact with air, just the right amount of fuel and the amount of combustion air composition in order to achieve combustion efficiency, but also reduce gas emissions and achieve energy-saving dual, very convenient. Gas steam boiler may be configured according to the actual amount of steam required, thus reducing waste of energy. The higher the degree of matching the actual demand and supply theory, better energy-saving effect. Continuous sewage heat can be utilized by a heat exchanger, thereby increasing the water temperature deoxygenated water. Gas-fired steam boilers and other machinery and equipment, more in line with current environmental requirements, so it has been widely used.