Fully Automatic 1 Ton gas fired Steam Boiler
Small series to introduce horizontal fully automatic 1 ton fired steam boiler steam boiler arch horizontal tube plate with threaded pipe drum composition, high heat transfer efficiency, boost fast enough output, high overload capability, hard fouling smoke tube. Today, let us together look at it. Horizontal welding binding sites steam boiler using high-temperature region and large machining bundle special treatment to ensure the welding quality and service life. Flammable, widely used fuel, burn bituminous coal, anthracite coal, firewood, industrial waste, organic waste and so on. It solves the problem of tube plate crack, eliminating the dead zone at the bottom of the drum, good water cycle effect, prevent the lower drum drum kits. Horizontal steam boiler compact structure, small dimensions and saves capital investment, easy installation, tipping valves, and piping to run hydropower. Stable, easy adjustment, the unique design of air sealing, bank up a fire a long time. Times atmospheric pollutants are oxides of dust, sulfur and nitrogen contained in horizontal steam boiler flue gas, which can achieve emissions targets Protection index when a predetermined number of times to unpurified. These substances emissions control combustion pretreatment, improved combustion techniques, dust removal, desulfurization and denitration. By means of a high chimney stack can reduce the concentration of pollutants in the atmosphere of the area.
Boiler fire phenomenon, how to do 1, furnace pressure fluctuations or to limit and alarm. 2, no flame detector flame, flame flameless television display. 3, flue gas oxygen abnormal fluctuations. 4, steam pressure steam temperature dropped drastically. 5, furnace black, black smoke chimney. 6, the flue gas temperature is reduced. 7, MFT action, turbine trip, splitting the unit. Cause 1, the furnace combustion conditions organizations unreasonable, improper wind coal proportion. 2, the load is too low, unstable combustion conditions without oil combustion vote, or vote, although oil but not good combustion results. 3, cast oil, poor quality oil, oil spray gun is bad, low oil pressure, oil system failure. 4, poor coal quality, coal is too rough, the water is too large pulverized coal combustion adjustment is not timely. 5, the primary air temperature, air pressure is too low. 6, boiler MFT protection action. 7, a large area of the furnace coke collapse, smashing off the flame. 8, severe water wall pipe explosion will blow out the flame. 9, all coal-fired condition, mill pulverizing system failure caused most or all trips. 10, a part of auxiliary machinery such as a fan, blower, fan, air preheater tripped, causing unstable furnace combustion conditions. 11, sootblowing properly, resulting in a large number of normal operation of the furnace ash effects of fire inspection of the boiler. 12, bottom seal damage. Treatment 1, the boiler fire, MFT should be action, otherwise manual MFT. 2, normal inspection device linkage linkage MFT, confirm that all fuel cut. 3. quickly identify the cause, try to eliminate the boiler can be re-ignition, the recovery unit operation. 4, when the mill started again after the trip, the trip must be the primary air tube mill full purge. 5, the MFT operation, checks, Fan normal operation, automatic furnace vent. 6, the MFT movement, check all the secondary purge air damper position is set, the total air volume is automatically adjusted to 30 ~ 40% BMCR sufficiently purged air volume. 7, the MFT operation, when the turbine is in a state disk drive, the disk drive must continue until the normal turbine eccentricity, before re turn red. 8, if temporarily unable to identify or eliminate the cause, restart and could threaten personal safety equipment, non-start. 9, processing according to the corresponding predetermined remaining MFT.
Beijing New Energy Automobile Co., Ltd. is China's first to operate independently and gain new energy automobile production qualification of new energy auto companies, mainly engaged in new energy vehicles and key parts and components research and development, production, sales and service business segments, and the layout intelligent manufacturing, energy management, smart travel, Internet +, and other strategic emerging industries. In the new energy automobile manufacturing process, and a series of paint drying processes can not do without the help of hot water boiler. Due to the company before the device has reached less than the growing production needs, the introduction of the 2017 mid-tail electric company producing heating pressure hot water boiler (CEDR0.7--95 / 70-Ⅱ).
Coal-fired boilers to gas boilers benefits and precautions With the rapid development of national energy-saving environmental protection, the traditional coal-fired boiler can not meet the needs of the times. Therefore, the coal-fired boiler biomass boiler or gas boiler has become in many boiler user's choice. Before the transformation, to understand the difference between .1 and gas boiler fired boiler. Circulating fluidized bed combustion boiler fired by coal crushing device fluidized combustion process, the coal by crushing device percutaneously into the bunker through a the spreading coal coal injecting air into the furnace; circulating ash by heating, fluidized combustion process. When the coal into a gas fuel is injected directly into the combustor for combustion. 2. Combustion of Coal is mainly composed of C, H, O, N, S, ash and moisture and other elements. Generated when coal SO2, SO3, NOx ash and moisture, and SO2, SO3, NOx from flue gas emitted into the atmosphere, pollute the environment and cause harm to humans. The main components of the exhaust gas and coke are CO and H2. The main produce CO2 and H2 post-combustion, much lower than coal-fired boiler SO2, SO3 and NOX emissions. 3. Ventilation pressurized combustion coal combustion boiler used in a combustion mode. The bottom of the combustion process through the induced draft fan with fan and completed. In the combustion of coal, it requires a lot of air. Gas under a slight positive pressure in the boiler or burner slightly negative pressure, which requires less airflow. Burner air may be pre-mixed with natural gas. 4. coal boiler control reasons, material thickness, amount of wind, the wind volume, wind and other than coal, coal-fired boiler is difficult to automatically adjust the operating parameters of the boiler according to the load. However, fewer factors gas boiler, the burner valve can be adjusted according to the size of the load, easy to implement automatic control. Coal-fired boiler to a gas boiler Notes: Main results are as follows: (1) small boiler, the coal-fired boiler to a gas boiler, i.e. the negative pressure of combustion from the original to the current combustion slight positive pressure, and must pay attention to the furnace wall structure sealing problems. Closely related (2) selection and arrangement of the burner and furnace, the degree of filling of the flame in the furnace is preferably not formed dead air, to avoid the interference of adjacent flame burners, to avoid interference from adjacent burner flame. Unburned gas - air mixture should not be in contact with a heated surface, in order to avoid incomplete combustion. Gas combustion. Gas burner arrangement disposed conduit and ducts should be considered reasonable gas pipe and duct arrangement, ease of operation, inspection and maintenance. (3) the transformation of coal-fired boilers is mechanized layered gas boiler should be removed before the arch and the arch, and the bottom heating surface increases, in place of the grate, the grate to prevent overheating. Gas Velocity (4) on heat transfer surface of the fly ash is not restricted abrasion conditions, convection heating surface heat transfer coefficient is increased, increasing the pressure in the boiler where H is unduly increased. Boiler erosion surface. At this time, the capacity of the boiler should be noted that the steam separator to ensure the quality of the steam.